Therm-A-Stop Fire & Smoke Seals

From £0.96 Per 1-24 x 2.1 metre lengths (Prices shown exclude VAT)
Brand: Intumescent Seals
Product Code:
Availability:
Select Required Size:
10x4mm
15x4mm
20x4mm
25x4mm
30x4mm
38x4mm
Available in the below colours:
White
Brown
Black
Cream
Grey
Select brush height:
Standard
6mm
9mm
Other Quantities available and Bulk Offers:
Per 1-24 x 2.1 metre lengths £0.96
Per 25-49 x 2.1 metre lengths £0.95
Per 50+ x 2.1 metre lengths £0.94
Per 1 x 2.1 metre lengths £1.98
Per 1 x 2.1 metre lengths £2.15
Per 1-24 x 2.1 metre lengths £1.34
Per 25-49 x 2.1 metre lengths £1.32
Per 50+ x 2.1 metre lengths £1.30
Per 1 x 2.1 metre lengths £2.52
Per 1 x 2.1 metre lengths £2.64
Per 50 x 2.1 metre lengths £1.30
Per 1-24 x 2.1 metre lengths £1.84
Per 25-49 x 2.1 metre lengths £1.81
Per 50+ x 2.1 metre lengths £1.79
Per 1 x 2.1 metre lengths £2.96
Per 1 x 2.1 metre lengths £3.00
Per 25-49x 2.1 metre lengths £1.81
Per 1 x 2.1 metre lengths £2.70
Per 1 x 2.1 metre lengths £4.03
Per 1 x 2.1 metre lengths £6.90
Description
Specification
Additional Information
Product Downloads

THERM-A-STOP’s chemical formulation is based on expandable graphite which is manufactured in the UK to our unique formulation. The seal is supplied in a PVC casing. Unlike many other types of intumescent material, THERM-A-STOP is unaffected by atmospheric moisture and therefore does not require any further protection. It is also immune to degradation by carbon dioxide in the atmosphere.

THERM-A-STOP is supplied as standard in brown or white casings although black, grey and a cream finish are also available to order.*

Nominal sizes are available in the following dimensions:

10 mm x 4 mm, 15 mm x 4 mm, 20 mm x 4 mm, 25 mm x 4 mm, 30 mm x 4 mm 38mm x 4 mm in 2100mm lengths.

The standard height of the pile projects 5 mm from the PVC holder - and is generally suitable for sealing an average gap of 3 mm to 4 mm between door and frame. If wider gaps have to be sealed, a higher brush profile can be supplied.

THERM-A-STOP meets the requirements for fire and smoke performance of BS476 : parts 20, 22 & 31.1 . It has also passed the more exacting standards required by Certifire.

The installation of intumescent fire and ambient temperature smoke seals around fire door assemblies is essential to meet the requirements of BS5588 ‘Fire precautions in the design and construction of buildings’. Throughout its code of practice, BS5588 designates certain fire resistant doorsets which are required to retard the passage of smoke at ambient temperatures with the suffix S. Hence:-

FD20S represents a Fire Door with no less than 20 minutes integrity.

FD30S represents a Fire Door with no less than 30 minutes integrity.

FD60S represents a Fire Door with no less than 60 minutes integrity.

THERM-A-STOP has been designed for use in fire resisting door assemblies which have been designated as smoke control doors. The seal slows the spread of smoke and fire through a building by reducing the flow of smoke and air through the gaps between the leaf and the frame or an adjacent leaf edge during the early stages of a fire. Activated by heat, the material rapidly expands to seal the air gaps between the leaf and frame, insulating and protecting the gaps - thereby significantly slowing the spread of fire through the doorset. THERM-A-STOP is suitable for use on fire resisting door assemblies manufactured from timber, steel or combinations of both.

THERM-A-STOP intumescent fire and ambient temperature smoke seals are available in PVC holders which are either 4 mm or 5 mm deep. For some latched single-leaf, single swing 30 minute (FD30S) timber fire resisting door assemblies, a single 10 mm x 4 mm strip down each jamb and across the head will usually meet these requirements but some manufacturers use 15 mm x 4 mm seals to give a more consistent and reliable door performance.

Some latched single-leaf, single swing 60 minute (FD60S) timber fire resisting door assemblies will satisfy the requirements of BS476 : parts 20 and 22 (1987) test procedures when

fitted with a single 20 mm x 4 mm strip across the head and down both jambs and some require two strips of 15 mm x 4 mm strip. There are several other combinations of seals for 60 minute applications so it is usually necessary to

consult the door or seal manufacturer to identify the seals required.

Steel doors do not usually require intumescent seals. Fire doors tested to BSEN 1634 (the new European Standard which is more onerous than BS476) usually require better sealing performance and these seals are generally door specific. For advice, please contact Firewise.

Test Evidence
Chiltern test RF99141B.pdf
Date Added: 17/08/2017
File Type: pdf
Certifications
CF3872015-2020ISL.pdf
Date Added: 17/08/2017
File Type: pdf
Technical PDFs
Therm-A-Stop.pdf
Date Added: 17/08/2017
File Type: pdf
Description

THERM-A-STOP’s chemical formulation is based on expandable graphite which is manufactured in the UK to our unique formulation. The seal is supplied in a PVC casing. Unlike many other types of intumescent material, THERM-A-STOP is unaffected by atmospheric moisture and therefore does not require any further protection. It is also immune to degradation by carbon dioxide in the atmosphere.

Specification

THERM-A-STOP is supplied as standard in brown or white casings although black, grey and a cream finish are also available to order.*

Nominal sizes are available in the following dimensions:

10 mm x 4 mm, 15 mm x 4 mm, 20 mm x 4 mm, 25 mm x 4 mm, 30 mm x 4 mm 38mm x 4 mm in 2100mm lengths.

The standard height of the pile projects 5 mm from the PVC holder - and is generally suitable for sealing an average gap of 3 mm to 4 mm between door and frame. If wider gaps have to be sealed, a higher brush profile can be supplied.

THERM-A-STOP meets the requirements for fire and smoke performance of BS476 : parts 20, 22 & 31.1 . It has also passed the more exacting standards required by Certifire.

Additional Information

The installation of intumescent fire and ambient temperature smoke seals around fire door assemblies is essential to meet the requirements of BS5588 ‘Fire precautions in the design and construction of buildings’. Throughout its code of practice, BS5588 designates certain fire resistant doorsets which are required to retard the passage of smoke at ambient temperatures with the suffix S. Hence:-

FD20S represents a Fire Door with no less than 20 minutes integrity.

FD30S represents a Fire Door with no less than 30 minutes integrity.

FD60S represents a Fire Door with no less than 60 minutes integrity.

THERM-A-STOP has been designed for use in fire resisting door assemblies which have been designated as smoke control doors. The seal slows the spread of smoke and fire through a building by reducing the flow of smoke and air through the gaps between the leaf and the frame or an adjacent leaf edge during the early stages of a fire. Activated by heat, the material rapidly expands to seal the air gaps between the leaf and frame, insulating and protecting the gaps - thereby significantly slowing the spread of fire through the doorset. THERM-A-STOP is suitable for use on fire resisting door assemblies manufactured from timber, steel or combinations of both.

THERM-A-STOP intumescent fire and ambient temperature smoke seals are available in PVC holders which are either 4 mm or 5 mm deep. For some latched single-leaf, single swing 30 minute (FD30S) timber fire resisting door assemblies, a single 10 mm x 4 mm strip down each jamb and across the head will usually meet these requirements but some manufacturers use 15 mm x 4 mm seals to give a more consistent and reliable door performance.

Some latched single-leaf, single swing 60 minute (FD60S) timber fire resisting door assemblies will satisfy the requirements of BS476 : parts 20 and 22 (1987) test procedures when

fitted with a single 20 mm x 4 mm strip across the head and down both jambs and some require two strips of 15 mm x 4 mm strip. There are several other combinations of seals for 60 minute applications so it is usually necessary to

consult the door or seal manufacturer to identify the seals required.

Steel doors do not usually require intumescent seals. Fire doors tested to BSEN 1634 (the new European Standard which is more onerous than BS476) usually require better sealing performance and these seals are generally door specific. For advice, please contact Firewise.

Product Downloads
Chiltern test RF99141B.pdf
Date Added: 17/08/2017
File Type: pdf
CF3872015-2020ISL.pdf
Date Added: 17/08/2017
File Type: pdf
Therm-A-Stop.pdf
Date Added: 17/08/2017
File Type: pdf

View our most popular products

Ceramic Fibre Tapes

Ceramic Fibre Tape is a specialised tape based on ceramic fibres which is supplied on single strand reels for use when glazing a...

View Product

RF1 60 Minute Glazing Kits

Lorient’s RF1™ glazing system comprises: -A pair of bead applied intumescent glazing seals (RG2704).A sodium silicate intumescent...

View Product

Handy Foam B1

FM190 (gun grade) and FM170 (hand held) are fire rated gun grade and hand held expanding polyurethane foam. They can provide up...

View Product