Therm-A-Plate

Intumescent letterbox liner

Intumescent letterbox liner
THERM-A-PLATE (INTUMESCENT LETTERBOX LINER)A cost effective method of fire proofing letter apertures in doors |
INTRODUCTION It is increasingly common to find that entrance doors to flats and apartments in tower blocks and houses in multiple occupation, are fire resisting to 30 or 60 minutes rating. As these doors are effectively external doors, many have apertures cut in them to serve as letter boxes, but this unfortunately compromises the doorleaves integrity. THERM-A-PLATE offers a simple DESCRIPTION A THERM-A-PLATE kit comprises of three pieces of THERM-A-FLEX graphite based intumescent material. This material is renowned for its longevity and resistance to degradation by atmospheric influences. The intumescent strips are pre-cut to the correct width for 45mm and 54mm thick doorleaves. The intumescent materials are backed with a high bond strength |
self-adhesive tape for ease of PERFORMANCE The performance of the THERM-A-PLATE kits has been proven in fire tests carried out to BS476 Part 22 (1987).
TEST RESULTS Test results (time to failure in minutes) are shown for 45mm and 54mm doors with different aperture sizes. Test reports DFR 9807141, DFR 9804271,
|
AVAILABILITY THERM-A-PLATE intumescent letter plate kits are produced in five standard aperture sizes to suit both 30 and 60 minute fire doors.
Other sizes are available on request. INSTALLATION The kit is supplied in pieces backed with self adhesive tape and these are bonded to the inside sides of the aperture. The faces of the aperture must be clean, dry and dust free for optimum adhesion. Kits may be trimmed to suit the aperture size as required. It is recommended that metal letter plates are used to comply with the recommendations in BS8214 (1990) and the largest aperture requires a metal tidy but does not have end pieces of intumescent. |
||||||||||||||||||||||||||